欧美黑人性猛交xxxⅹooo,人妻精品无码一区二区三区,欧美日韩国产一区二区三区不卡,av中文字幕一区人妻

您的瀏覽器版本過低,為保證更佳的瀏覽體驗,請點擊更新高版本瀏覽器

以后再說X

歡迎訪問瑞昌明盛自動化設備有限公司網(wǎng)站!

圖片名

全國訂購熱線:
+86 15270269218E-mail:[email protected]

ABB >>

A-B>>

GE>>

BENTLY>>

PROSOFT 5304-MBP-PDPM邏輯通訊模塊

PROSOFT 5304-MBP-PDPM邏輯通訊模塊

PROSOFT 5304-MBP-PDPM邏輯通訊模塊功能代碼05–廣播命令Modbus實施:強制單線圈PQM實施:執(zhí)行操作此功能代碼允許主機請求特定通信鏈路上的所有PQM清除所有需求數(shù)據(jù)。如果從地址被發(fā)送為0,則PQM將識別分組為廣播命令。以下是清除所有需求數(shù)據(jù)的廣播命令示例。功能代碼06–存儲單設定點Modbus實現(xiàn):預設單寄存器PQM實現(xiàn):存儲單設點此命令允許主機將單個設定點存儲到PQM的存...

  • 功能特性
  • 參數(shù)規(guī)格
  • 視頻
  • 應用案例
  • 下載

PROSOFT 5304-MBP-PDPM邏輯通訊模塊

    PROSOFT 5304-MBP-PDPM邏輯通訊模塊

    功能代碼05–廣播命令Modbus實施:強制單線圈PQM實施:執(zhí)行操作此功能代碼允許主機請求特定通信鏈路上的所有PQM清除所有需求數(shù)據(jù)。如果從地址被發(fā)送為0,則PQM將識別分組為廣播命令。以下是清除所有需求數(shù)據(jù)的廣播命令示例。功能代碼06–存儲單設定點Modbus實現(xiàn):預設單寄存器PQM實現(xiàn):存儲單設點此命令允許主機將單個設定點存儲到PQM的存儲器中。從屬設備對該功能代碼的響應是響應整個主傳輸。消息格式和示例:請求從設備17將值01E4存儲在設定點地址1020中。本示例中的傳輸完成后,設置點地址1020將包含值01E4。功能代碼07–讀取設備狀態(tài)Modbus實施:讀取異常狀態(tài)PQM實施:讀取設備狀態(tài)這是一個用于快速讀取所選設備狀態(tài)的功能。短消息長度允許快速讀取狀態(tài)。根據(jù)從屬設備的狀態(tài),返回的狀態(tài)字節(jié)將具有設置為1或0的單個位。

    Function Code 05 – Broadcast Command Modbus Implementation: Force Single Coil PQM Implementation: Execute Operation This function code allows the master to request all PQMs on a particular communications link to Clear All Demand Data. The PQM will recognize a packet as being a broadcast command if the SLAVE ADDRESS is transmitted as 0. Below is an example of the Broadcast Command to Clear All Demand Data.Function Code 06 – Store Single Setpoint Modbus Implementation: Preset Single Register PQM Implementation: Store Single Setpoint This command allows the master to store a single setpoint into the memory of a PQM. The slave response to this function code is to echo the entire master transmission. MESSAGE FORMAT AND EXAMPLE: Request slave 17 to store the value 01E4 in setpoint address 1020. After the transmission in this example is complete, setpoint address 1020 will contain the value 01E4.Function Code 07 – Read Device Status Modbus Implementation: Read Exception Status PQM Implementation: Read Device Status This is a function used to quickly read the status of a selected device. A short message length allows for rapid reading of status. The status byte returned will have individual bits set to 1 or 0 depending on the status of the slave device.


    GE DS3820DMCB渦輪機控制板(圖1)         GE DS3820DMCB渦輪機控制板(圖1)         GE DS3820DMCB渦輪機控制板(圖1)


    微信圖片_20221017083800.jpg

    微信圖片_20230202095437_副本_副本.jpg


    品牌:PROSOFT

    型號:PROSOFT 5304-MBP-PDPM邏輯通訊模塊

    質保:365天

    成色:全新/二手



圖片名 客服

在線客服 客服一號