欧美黑人性猛交xxxⅹooo,人妻精品无码一区二区三区,欧美日韩国产一区二区三区不卡,av中文字幕一区人妻

您的瀏覽器版本過(guò)低,為保證更佳的瀏覽體驗(yàn),請(qǐng)點(diǎn)擊更新高版本瀏覽器

以后再說(shuō)X

歡迎訪(fǎng)問(wèn)瑞昌明盛自動(dòng)化設(shè)備有限公司網(wǎng)站!

圖片名

全國(guó)訂購(gòu)熱線(xiàn):
+86 15270269218E-mail:[email protected]

ABB >>

A-B>>

GE>>

BENTLY>>

HIMA F2102處理器卡件

HIMA F2102處理器卡件

HIMA F2102處理器卡件是符號(hào)位。范圍分辨率范圍限制0至20 mA 15位0至32767 4至20 mA 16位0至3296763 0至10 Vdc 15位0到32767-10 Vdc至10 Vdc 16位-32768至32767 10.3.5.1狀態(tài)數(shù)據(jù):ALG392此模塊使用8或16個(gè)離散輸入位,如配置所示。低8位用于模塊狀態(tài)信息,如下圖所示。在當(dāng)前模式下,各個(gè)通道也可以報(bào)告斷線(xiàn)診斷。這...

  • 功能特性
  • 參數(shù)規(guī)格
  • 視頻
  • 應(yīng)用案例
  • 下載

HIMA F2102處理器卡件

    HIMA F2102處理器卡件

    是符號(hào)位。范圍分辨率范圍限制0至20 mA 15位0至32767 4至20 mA 16位0至3296763 0至10 Vdc 15位0到32767-10 Vdc至10 Vdc 16位-32768至32767 10.3.5.1狀態(tài)數(shù)據(jù):ALG392此模塊使用8或16個(gè)離散輸入位,如配置所示。低8位用于模塊狀態(tài)信息,如下圖所示。在當(dāng)前模式下,各個(gè)通道也可以報(bào)告斷線(xiàn)診斷。這些診斷以高8位報(bào)告,如圖所示:63 in 4-20可配置為作為電壓輸出或電流輸出運(yùn)行,而不是同時(shí)運(yùn)行。10.3.7配置:ALG392參數(shù)描述值默認(rèn)值激活信道掃描的信道數(shù)1到8 1模塊輸出數(shù)據(jù)參考地址輸出范圍0、+10 Vdc±10 Vdc 4、20 mA 0、20 mA 1、10 Vdc激活信道表示PLC CPU將掃描的信道數(shù)量。對(duì)STOP模式所做的選擇決定了當(dāng)從RUN(運(yùn)行)模式轉(zhuǎn)到STOP(停止)模式時(shí),該模塊上的輸出是否保持其最后狀態(tài)或默認(rèn)為零。%AQ參考地址參數(shù)選擇%AQ內(nèi)存中將開(kāi)始向模塊輸出數(shù)據(jù)的區(qū)域的起始位置。%I參考地址選擇%I內(nèi)存中該模塊狀態(tài)數(shù)據(jù)區(qū)域的起始位置。如果長(zhǎng)度設(shè)置為8,則只報(bào)告模塊狀態(tài)。如果長(zhǎng)度設(shè)置為16,則還將報(bào)告作為電流輸出運(yùn)行的信道的信道狀態(tài)。每個(gè)通道可設(shè)置為在四個(gè)輸出范圍之一上運(yùn)行:? 0至10 Vdc(默認(rèn)值)? -10 Vdc至+10 Vdc范圍? 4至20 mA和0至20 mA? 0至20 mA 10.3.8模擬輸出模塊4通道電流/電壓:IC695ALG004模擬輸出模塊8通道電流/電流:IC695AlG008 PACSystems*RX3i系統(tǒng)手冊(cè)第12節(jié)GFK-2314T 2019年9月模擬輸出模塊449模塊OK FIELD STATUS TB IC695ALG708 Q1 Q2 Q4 Q5 Q6 Q7 Q8圖304:IC695ALL708模擬電流/電壓輸出模塊IC695ALD704,提供四個(gè)非隔離的可配置電壓或電流輸出通道。模擬電流/電壓輸出模塊IC695ALG008(圖304)提供八個(gè)非隔離的可配置電壓或電流輸出通道??梢詾橐韵螺敵龇秶渲媚M通道:? 電流:0至20mA,4至20mA? 電壓:±10 Vdc,0至10 Vdc這些模塊可與盒型(IC694TBB032)、擴(kuò)展盒型(IC 694TBB132)、彈簧型(IC6914TBS032)或擴(kuò)展彈簧型(IC 6914TBS132)接線(xiàn)板一起使用。擴(kuò)展接線(xiàn)板提供屏蔽布線(xiàn)所需的額外護(hù)罩深度。有關(guān)接線(xiàn)板的更多信息,請(qǐng)參閱第17章。接線(xiàn)板單獨(dú)訂購(gòu)。這些模塊必須位于RX3i通用背板中。它們需要固件版本為3.0或更高版本的RX3i CPU。必須使用Machine Edition 5.0 SP3 Logic Developer PLC或更高版本進(jìn)行配置。10.3.9隔離+24V直流電源模塊必須從外部電源接收其24Vdc電源。外部電源必須直接連接到此模塊的接線(xiàn)板。它不能通過(guò)RX3i通用背板上的TB1連接器連接。10.3.10特點(diǎn):ALG704和ALG708? 完全軟件可配置,無(wú)需設(shè)置模塊跳線(xiàn)? 單獨(dú)啟用或禁用通道? 夾緊和報(bào)警限值? 警報(bào)的鎖定? 可配置輸出偏置? 基于濾波器頻率的快速信道捕獲時(shí)間? 全自動(dòng)校準(zhǔn)? 車(chē)載錯(cuò)誤檢查? 每個(gè)通道可配置的縮放和偏移? 每個(gè)通道可選擇高報(bào)警、低報(bào)警、高高報(bào)警、低低報(bào)警檢測(cè)和報(bào)告? 模塊故障報(bào)告? 可配置的保持上次狀態(tài)或輸出默認(rèn)值? 模塊支持插入和取出通電的RX3i通用背板。參見(jiàn)第2.6.4.1節(jié)熱插拔。? 模塊支持使用WinLoader軟件實(shí)用程序(如果主機(jī)CPU具有串行端口)或使用基于Web的工具(如果主機(jī)沒(méi)有串行端口)進(jìn)行固件升級(jí)。固件升級(jí)套件中包含說(shuō)明。2

    .is the sign bit. Range Resolution Range Limits 0 to 20 mA 15 bits 0 to 32767 4 to 20 mA 15 bits 0 to 3276763 0 to 10 Vdc 15 bits 0 to 32767 -10 Vdc to 10 Vdc 16 bits - 32768 to 32767 10.3.5.1 Status Data: ALG392 This module uses either 8 or 16 discrete input bits, as configured. The lower 8 bits are used for module status information as displayed in the following figure. In current mode, individual channels can also report Broken Wire diagnostics. Those diagnostics are reported in the upper eight bits, as shown: 63 In 4-20 can be configured to operate as a voltage output or a current output - not both simultaneously. 10.3.7 Configuration: ALG392 Parameter Description Values Default Values Active Channels Number of channels scanned 1 through 8 1 Reference Address for Module Output Data Starting Type of Output Range 0, +10 Vdc ±10 Vdc 4, 20 mA 0, 20 mA 0, 10 Vdc Active Channels indicates the number of channels that will be scanned by the PLC CPU. The choice made for STOP Mode determines whether the outputs on this module will hold their last states or default to zero when the goes from RUN to STOP mode. The %AQ Reference Address parameter selects the start of the area in the %AQ memory where the output data to the module will begin. The %I Reference Address selects the start of the area in %I memory for the status data of this module. If the length is set to 8, then only module status will be reported. If the length is set to 16, channel status will also be reported for channels that are operating as current outputs. Each channel can be set up to operate on one of four output ranges: ? 0 to 10 Vdc (default) ? -10 Vdc to +10 Vdc range ? 4 to 20 mA, and 0 to 20 mA ? 0 to 20 mA 10.3.8 Analog Output Module 4-Channel Current/Voltage: IC695ALG704 Analog Output Module 8-Channel Current/Voltage: IC695ALG708 PACSystems* RX3i System Manual Section 12 GFK-2314T Sept. 2019 Analog Output Modules 449 MODULE OK FIELD STATUS TB IC695ALG708 Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 Figure 304: IC695ALG708 The Analog Current/Voltage Output module, IC695ALG704, provides four non-isolated configurable voltage or current output channels. The Analog Current/Voltage Output module, IC695ALG708 (Figure 304), provides eight non-isolated configurable voltage or current output channels. Analog channels can be configured for these output ranges: ? Current: 0 to 20mA, 4 to 20mA ? Voltage: ± 10 Vdc, 0 to 10 Vdc These modules can be used with a Box-style (IC694TBB032), Extended Boxstyle (IC694TBB132), Spring-style (IC694TBS032), or Extended Spring-style (IC694TBS132) Terminal Block. Extended terminal blocks provide the extra shroud depth needed for shielded wiring. Refer to Chapter 17 for more information about Terminal Blocks. Terminal Blocks are ordered separately. These modules must be located in an RX3i Universal Backplane. They require an RX3i CPU with firmware version 3.0 or later. Machine Edition Version 5.0 SP3 Logic Developer-PLC or later must be used for configuration. 10.3.9 Isolated +24Vdc Power The module must receive its 24Vdc power from an external source. The external source must be connected directly to the terminal block of this module. It cannot be connected via the TB1 connector on the RX3i Universal Backplane. 10.3.10 Features: ALG704 & ALG708 ? Completely software-configurable, no module jumpers to set ? Individually enable or disable channels ? Clamping and Alarm Limits ? Latching of Alarms ? Configurable output bias ? Rapid channel acquisition times based on filter frequency ? Full auto-calibration ? On-board error-checking ? Configurable scaling and offsets per channel ? High alarm, low alarm, high-high alarm, low-low alarm detection and reporting selectable per channel ? Module fault reporting ? Configurable Hold Last State or Output Defaults ? Module supports insertion into and removal from an RX3i Universal Backplane which is under power. Refer to Hot Insertion and Removal, Section 2.6.4.1. ? Module supports firmware upgrades using the WinLoader software utility (if the host CPU has a serial port) or using a Web-based tool (if the host CPU has no serial port). Instructions are included with the firmware upgrade kit.2

    2022.11.15.jpg

    手機(jī)輪播圖2(1)_副本.jpg

    fa405aeea632aa6912154382925a28b_副本.jpg



    品牌: HIMA

    型號(hào):HIMA F2102 

    質(zhì)保:365天

    成色:全新/二手

    發(fā)貨方式:快遞發(fā)貨


圖片名 客服

在線(xiàn)客服 客服一號(hào)