s–版本MA和更高版本L及更早版本不支持熱插拔。IC694APU300是–修訂版CA和更高版本BA和更早版本不支持熱插拔。IC693APU305是IC694APU305是IC 693BEM331是MaxON冗余系統(tǒng)中包含的Genius總線控制器模塊不應(yīng)安裝或從作為主機(jī)運(yùn)行的PLC中移除。如果某個(gè)模塊從主機(jī)中刪除,然后重新安裝,則在下一次備份到主機(jī)轉(zhuǎn)換之前,該模塊的輸出將不會(huì)啟用。PACSystems*RX3i系統(tǒng)手冊(cè)第3節(jié)GFK-2314T 2019年9月安裝38目錄號(hào)熱交換兼容說(shuō)明/熱交換能力限制IC694BEM331是任何時(shí)候從活動(dòng)系統(tǒng)中移除Genius總線控制器,都有可能會(huì)中斷總線,并對(duì)相應(yīng)的I/O設(shè)備產(chǎn)生后續(xù)影響。對(duì)于需要在線維護(hù)的系統(tǒng),建議使用雙(冗余)Genius總線。否則,BEM331可以熱交換。IC695CMM002是IC695CMM004是IC695CMX128是IC693DSM324是IC694DSM324是IC695ECM850是IC695EDS001是IC695EIS001是IC 695ETM001是IC69GCG001是Genius通信網(wǎng)關(guān)需要外部24Vdc電源,并且不從RX3i背板獲取電源。因此,更換GCG001不會(huì)影響PLC。但是,如果不斷開其電源,則無(wú)法執(zhí)行此操作。如果配置為支持Genius熱備用,將允許單個(gè)GCG001丟失;否則不會(huì)。IC695HSC304是IC695HSC308是IC693MDL230是IC694MDL230是IC 693MDL231是IC695MDL231是IC 694MDL240是PACSystems*RX3i系統(tǒng)手冊(cè)第3節(jié)GFK-2314T 2019年9月安裝39目錄號(hào)熱插拔兼容說(shuō)明/在從RX3i通用背板熱插拔之前移除,熱插拔后重新安裝。IC694MDL634是IC693MDL635是IC691MDL635是IC693M DL645是熱插拔只能在現(xiàn)場(chǎng)側(cè)接線板從模塊上拆下的情況下執(zhí)行。接線板符合PACSystems*RX3i系統(tǒng)手冊(cè)第3節(jié)GFK-2314T 2019年9月安裝40目錄號(hào)熱插拔兼容說(shuō)明/熱插拔能力限制IC694MDL645是的,在從RX3i通用背板熱插拔之前拆除,熱插拔后重新安裝。IC693MDL646是熱插拔只能在現(xiàn)場(chǎng)側(cè)接線板從模塊上拆下的情況下進(jìn)行。在從RX3i通用背板熱插拔之前拆除接線板,并在熱插拔后重新安裝。IC694MDL646是IC693MDL648是熱插拔只能在現(xiàn)場(chǎng)側(cè)接線板從模塊上拆下的情況下執(zhí)行。接線板應(yīng)為IC694MDL754是IC694MDL 758是IC695MDL765是IC693MDL916是IC691MDL916是IC695PBM300是IC695PBS301是IC695PMM335是僅當(dāng)PLC處于停止模式IC695PNC001是IC695PRS015是IC695PSA140是僅當(dāng)冗余電源存在且每個(gè)電源都通電時(shí)才能進(jìn)行熱插拔。IC695PSD140是僅當(dāng)存在冗余電源且每個(gè)電源都已通電時(shí)才可熱插拔。IC694PSM001是PACSystems*RX3i系統(tǒng)手冊(cè)第3節(jié)GFK-2314T 2019年9月安裝42目錄號(hào)熱插拔兼容說(shuō)明/熱插拔能力限制IC695RMX128是IC695RMX228是警告在系統(tǒng)通電的情況下插入或移除模塊可能會(huì)導(dǎo)致電弧。這可能會(huì)導(dǎo)致現(xiàn)場(chǎng)設(shè)備發(fā)生意外和潛在的危險(xiǎn)動(dòng)作。電弧在危險(xiǎn)場(chǎng)所存在爆炸風(fēng)險(xiǎn)。在拆除或插入模塊之前,確保該區(qū)域無(wú)危險(xiǎn)或切斷系統(tǒng)電源。警告:請(qǐng)勿在背板通電的情況下插入或移除RX3i串行擴(kuò)展背板或Series 90-30擴(kuò)展背板中的模塊。這可能導(dǎo)致PLC停止或故障??赡軙?huì)導(dǎo)致人員受傷和模塊或背板損壞。如果PLC處于RUN(運(yùn)行)模式,則在斷電時(shí),不會(huì)更新該背板的I/O數(shù)據(jù)。2.6.4.2不支持熱插拔以下模塊不支持熱插入和熱插拔。當(dāng)機(jī)架通電時(shí),請(qǐng)勿嘗試插入或取出它們。
s – Revision MA & later Revision L and earlier do not support hot swap. IC694APU300 Yes – Revision CA & later Revision -BA and earlier do not support hot swap. IC693APU305 Yes IC694APU305 Yes IC693BEM331 Yes Genius Bus Controller modules that are included in a MaxON redundancy system should not be installed or removed from the PLC that is operating as a Master. If a module is removed from the Master and then re-installed, the outputs for that module will not be enabled until the next Backup-to-Master transition. PACSystems* RX3i System Manual Section 3 GFK-2314T Sept. 2019 Installation 38 Catalog Number Hot-Swap Compatible Notes / Restrictions on Hot Swap Capability IC694BEM331 Yes Any time a Genius Bus Controller is removed from an active system, there is a possibility that the bus may be disrupted with a subsequent impact on the corresponding I/O devices. For systems that require online maintainability, it is recommended that dual (redundant) Genius busses be used. Otherwise, the BEM331 can be hot-swapped. IC695CMM002 Yes IC695CMM004 Yes IC695CMX128 Yes IC693DSM324 Yes IC694DSM324 Yes IC695ECM850 Yes IC695EDS001 Yes IC695EIS001 Yes IC695ETM001 Yes IC695GCG001 Yes The Genius Communications Gateway requires an external 24Vdc power supply and does not draw power from the RX3i backplane. Swapping out the GCG001 will therefore not impact the PLC. However, this cannot be performed without disconnecting its power supply. If configured to support Genius Hot Standby, the loss of a single GCG001 will be tolerated; otherwise not. IC695HSC304 Yes IC695HSC308 Yes IC693MDL230 Yes IC694MDL230 Yes IC693MDL231 Yes IC694MDL231 Yes IC693MDL240 Yes PACSystems* RX3i System Manual Section 3 GFK-2314T Sept. 2019 Installation 39 Catalog Number Hot-Swap Compatible Notes / removed before hot extraction from the RX3i Universal Backplane and re-installed after hot insertion. IC694MDL634 Yes IC693MDL635 Yes IC694MDL635 Yes IC693MDL645 Yes Hot swap can only be performed with field side terminal block removed from the module. The terminal block is to PACSystems* RX3i System Manual Section 3 GFK-2314T Sept. 2019 Installation 40 Catalog Number Hot-Swap Compatible Notes / Restrictions on Hot Swap Capability IC694MDL645 Yes be removed before hot extraction from the RX3i Universal Backplane and re-installed after hot insertion. IC693MDL646 Yes Hot swap can only be performed with field side terminal block removed from the module. The terminal block is to be removed before hot extraction from the RX3i Universal Backplane and re-installed after hot insertion. IC694MDL646 Yes IC693MDL648 Yes Hot swap can only be performed with field side terminal block removed from the module. The terminal block is to be IC694MDL754 Yes IC694MDL758 Yes IC695MDL765 Yes IC693MDL916 Yes IC694MDL916 Yes IC695PBM300 Yes IC695PBS301 Yes IC695PMM335 Yes Hot-Swap can only be performed while PLC is in STOP mode IC695PNC001 Yes IC695PRS015 Yes IC695PSA140 Yes Hot-swappable only when redundant power supplies are present and each is powered up. IC695PSD140 Yes Hot-swappable only when redundant power supplies are present and each is powered up. IC694PSM001 Yes PACSystems* RX3i System Manual Section 3 GFK-2314T Sept. 2019 Installation 42 Catalog Number Hot-Swap Compatible Notes / Restrictions on Hot Swap Capability IC695RMX128 Yes IC695RMX228 Yes WARNING Inserting or removing a module with power applied to the system may cause an electrical arc. This can result in unexpected and potentially dangerous action by field devices. Arcing is an explosion risk in hazardous locations. Be sure that the area is non-hazardous or remove system power before removing or inserting a module. WARNING Do not insert or remove modules in RX3i Serial Expansion Backplanes or Series 90-30 Expansion Backplanes with power applied to the backplane. This could cause the PLC to stop or malfunction. Injury to personnel and damage to the module or backplane may result. If the PLC is in RUN mode, I/O data to/from this backplane will not be updated while power is removed. 2.6.4.2 Hot Insertion and Removal Not Supported The following modules do not support hot Insertion and removal. Do not attempt to insert or remove them while power is applied to the rack.